Auto-Pure 2400 / 2400M
Auto-Pure 2400 / 2400M
Auto-Pure 2400 / 2400M is a high-throughput automatic nucleic acid extraction equipment, based on the magnetic bead method to extract nucleic acid. The steps of pipetting, lysis, washing, elution and PCR set-up can be automatically completed in the workstation, one-stop operation without manual intervention. The maximum reaction system is 10 mL. It can extract 24×10 mL sample system at the same time. The automated operation steps avoid human error, and the experimental results are more reliable and repeatable.
Send us an inquiry and our team will respond within 24 hours.
Auto-Pure 2400 / 2400M is a high-throughput automatic nucleic acid extraction equipment, based on the magnetic bead method to extract nucleic acid. The steps of pipetting, lysis, washing, elution and PCR set-up can be automatically completed in the workstation, one-stop operation without manual intervention. The maximum reaction system is 10 mL. It can extract 24×10 mL sample system at the same time. The automated operation steps avoid human error, and the experimental results are more reliable and repeatable.
2400M includes a temperature change block with no cross- contamination. With the corresponding software, it can automate the entire process of methylation transfer, simplifying complicated experiments. In addition, the full-coverage UV sterilization system and negative pressure filter system effectively prevent cross- contamination.
Auto-Pure 2400: Automated Extraction + PCR Set-Up

Auto-Pure 2400M: Automated Extraction + Methylation Transfer + PCR Set-Up
Note: In addition to meeting the needs of automated nucleic acid extraction as 2400, 2400M can also automate the methylation transfer process. This step of "Quality control" is completed using the supporting instrument - Fluo-200 / 800 fluorometer.
01 Large Volume Extraction to Meet Special Needs
02 High-Precision Liquid Handling

03 Easy-to-Learn Operating Software
04 Methylation Transfer Special Functional Blocks (2400M)

Plate Layout

1 Sample Area
The sample barcode of each test tube is automatically scanned during sample rack loading.
2 Reagent Area
Include 100 mL reagent positions, 7 mL centrifuge tube positions and 1.5 mL / 2 mL centrifuge tube positions.
3 Tip Area
Include 5000 μL, 1000 μL and 200 μL tip racks.
4 PCR Reagent Area (Auto-Pure 2400)
RT. PCR reagent rack, optional refrigeration block.
Temperature Control Area (Auto-Pure 2400M)
Multi-stage automatic temperature change can be realized to meet the needs of methylation.
5 Waste Area
Used tips will be disposed into the waste container, whichcan intelligently calculate whether the tips are full andincrease the storage space.
6 Vortex Magnetic-Beads
Specially designed for magnetic beads, the vortexing is stable which improves the efficiency of the experiment.
7 PCR Setup Area
2400 can setup 4 detection item systems while 2400M is 2.
8 Nucleic Acid Extraction Area
Can extract 1-24 samples. Elution well 2 mL centrifuge tube design, the elution product can be used directly for subsequent experiments.
9 Pipetting Arm
Two-channel pipetting arm, 1×(50-5000 μL), suitable for 1 mL / 5 mL pipettors, 1×(1-200 μL), suitable for 200 μL pipettors.
2400M Special Application - Methylation Detection
2400M large volume extraction with special functional blocks and software design meet the requirements of methylation detection sample pre-processing experiments, realize the automation of the overall process, effectively reduce labor time and improve the stability of experimental results. The process shown in the figure below can be completed within 2400M except for "quality control":

Application - cfDNA Extraction
The Automatic Extraction Effect of Plasma from Tumor Patients
Compared with the combination of DNA Ladder and newborn bovine serum, the plasma environment of tumor patients is more complicated. In the manual method, the sample needs to undergo high-temperature lysis and other processes, while the automatic method adopts the method of directly mixing reagents such as lysis solution, magnetic beads, and binding solution with the sample and then running on the machine. In order to verify the extraction efficiency of this method for actual samples, 0.5 mL, 1 mL, and 4 mL of tumor patient plasma were taken for cfDNA extraction, and compared with the results of the same sample and manual extraction. The results showed that there was no significant difference in the yields of the two extraction methods under the three volumes, indicating that the automation of the reagents was well matched and met the needs of normal sample extraction.

0.5 mL, 1 mL, and 4 mL of tumor patient plasma were extracted using manual method and automated instruments respectively,with 50 μL elution volume. The results showed that there was no significant difference between the manual method and theautomatic method in terms of concentration or fragment size.
Specification
|
Model |
Auto-Pure 2400 / 2400M |
|
Function |
Automatic pipette samples / reagents, extract nucleic acid and setup PCR systems |
|
Information management |
Support external USB scanner, barcode scanning function, automatic scanning function |
|
Pipetting principle |
Air displacement pipetting technology |
|
Pipettor |
One 5000 μL pipettor and one 200 μL pipettor |
|
Pipetting range |
1-5000 μL |
|
Tips |
Allsheng tips, and other tips compatible with this instrument |
|
Liquid detection |
Pressure detection: liquid level detection, tip clogging detection and residual liquid detection |
|
Samples per run |
1-24 |
|
Process volume |
50-10000 μL |
|
Extraction uniformity |
CV ≤5 % |
|
Single sample consumables |
Support |
|
Heating temperature |
Elution and lysis temperature control: RT. ~120 °C |
|
Temp. control block (2400M)
|
4 °C~105 °C
|
|
UV sterilization
|
Separate UV lamp: extraction area, pipetting area and waste container area
|
|
Fan filter
|
Equipped with three HEPA filters
|
|
Instrument port
|
USB port
|
|
Power supply
|
220 V, 8 A , 50 / 60 Hz
|
|
Power
|
Standby 30 W, maximum 600 W
|
|
Noise
|
≤ 60 dB
|
|
Net weight
|
130 kg
|
Pipetting Accuracy
|
Pipettor |
200 μL |
1000 μL |
5000 μL |
|
Pipetting range |
1-200 μL |
5-1000 μL |
50-5000 μL |
|
Accuracy (A) |
1 μL: ±12 % 20 μL: ±3 % 100 μL: ±1 % 200 μL: ±1 % |
5 μL: ±5 % 100 μL: ±2 % 500 μL: ±1 % 1000 μL: ±1 % |
50 μL: ±6 % 500 μL: ±5 % 2500 μL: ±3 % 5000 μL: ±3 % |
|
Precision (CV) |
1 μL: ≤ 8 % 20 μL: ≤ 1.5 % 100 μL: ≤ 0.8 % 200 μL: ≤ 0.5 % |
5 μL: ≤ 2.5 % 100 μL: ≤ 1.25 % 500 μL: ≤ 0.4 % 1000 μL: ≤ 0.4 % |
50 μL: ≤ 3 % 500 μL: ≤ 2 % 2500 μL: ≤ 2 % 5000 μL: ≤ 1 % |
Ordering Information
|
Code |
Product description |
|
63-RS-17200-00 |
Auto-Pure 2400 |
|
63-RS-17220-00 |
Auto-Pure 2400M |
|
63-RS-17151-01 |
10 mL cartridge |
|
63-RS-17151-02 |
Magnetic rod comb |
|
63-RS-17151-03 |
5 mL cartridge |
|
63-RS-17151-05 |
2 mL storage tube |
|
63-RS-TT-200-R |
200 μL tips (natural, ABC box) |
|
63-RS-TT-1000-R |
1000 μL tips (natural, ABC box) |
|
63-RS-TT-5000C-HL |
5000 μL conduction tips (conduction, low retention, SBS box) |
|
Code |
Product description |
|
63-RS-17202-01 |
5 mL sample tube |
|
63-RS-17202-02 |
1.5 mL centrifuge tube |
|
63-RS-17202-03 |
2 mL centrifuge tube |
|
63-RS-17202-04 |
7 mL centrifuge tube |
|
63-RS-17202-06 |
8-strip PCR tube (0.2 mL) |
|
63-RS-17202-07 |
15 mL wide-mouth plastic bottle |
|
63-RS-17202-08 |
100 mL reservoir |
|
63-RS-17202-09 |
Medical waste packaging bag |
|
63-RS-17202-10 |
4000 μL tip |
|
Code |
Product description |
Specification |
|
RS-HSCF0101 |
Nucleic acid extraction or purification reagents (1 mL) |
10 T, 24 T, 50 T, 100 T |
|
RS-HSCF0102 |
Nucleic acid extraction or purification reagents (2 mL) |
24 T, 50 T |
|
RS-HSCF0104 |
Nucleic acid extraction or purification reagents (4 mL) |
24 T, 50 T |