Bioprep-6 / 24 / 24R Homogenizer

Back to Product Center
CELL PREPARATION63 views

Bioprep-6 / 24 / 24R Homogenizer

Request a Quote

Send us an inquiry and our team will respond within 24 hours.

Bioprep series is a fast and effective homogenizer with function of grinding, lysis and homogenizing by three-dimensional vibration and the coordination of the grinding beads (glass beads, silica beads, metal beads etc.). Effective to homogenize the animal or plant tissue, bacteria, fungus and so on. It also has extraordinary power for processing hard lysis samples such as spores, hair, bones, feces, soil etc. With the use of relevant kits, it can quickly, efficiently and steadily extract DNA / RNA / protein from samples in bulk, and preserve the integrity of biomacromolecule.

Comparison with Traditional Method

Traditional MethodHomogenizer
Sample preparationLiquid nitrogen grinding: mortar needs replacement for different samples, dangerous operation. Samples grinded one by one, time-consuming. Cross-contamination easy during grinding.No liquid nitrogen required, just put sample cut into grinding tube. Process multiple samples simultaneously. Single sample and single operation avoids cross-contamination. Recommend keeping grinding tube at low temperature (below -40 °C) for 12 hours before homogenization.
Grinding effectOperation difference and inconsistent grinding effect.Processing multiple samples at the same time, good homogeneity.

Key Points for Selecting Grinding Beads

The higher the hardness and toughness of the sample, the greater the density and diameter of the selected grinding beads. Multiple grinding beads can also be used to homogenize the same sample. Usually choose beads close to the size of the sample particles, and high density of the first choice. Grinding beads can be used repeatedly within a limited range by soaking them in cleaning agents for a long time, then rinsing them repeatedly with clean water, and finally rinsing them with pure water and drying them before use.

Grinding Tubes

  • Bioprep-6: simultaneous processing 6×2 mL / 1.5 mL tubes or 2×5 mL tubes.
  • Bioprep-24 / 24R: simultaneous processing 24×2 mL / 1.5 mL tubes or 12×5 mL tubes.

The grinding tubes must be with high toughness and low temperature resistance.

Applications

  • Suitable for homogeneous lysis of various plant tissues including roots, stems, leaves, flowers, fruits, seeds, etc.
  • Suitable for homogeneous lysis of various animal tissues including brain, organs, muscles, bones, glands, etc.
  • Suitable for homogeneous lysis of samples such as fungi and bacteria.
  • Suitable for grinding and lysis of food and drug ingredient analysis experiments.
  • Suitable for grinding and lysis of samples such as spores, hair, feces, soil, etc.

Specification

ModelBioprep-6Bioprep-24Bioprep-24R
Temperature range//-10 °C~40 °C
From RT. to 0 °C//<30 min
Temperature uniformity//≤±2 °C
DisplayLCDOLEDOLED
Speed range (m/s)4.00~7.00 m/s, increment 0.054.00~7.00 m/s, increment 0.054.00~7.00 m/s, increment 0.05
Speed range (rpm)2500~4350 rpm, increment 102430~4260 rpm, increment 102430~4260 rpm, increment 10
Cycle duration1 s - 90 s, increment 1 s1 s - 90 s, increment 1 s1 s - 90 s, increment 1 s
Pause time1 s - 90 s, increment 1 s1 s - 120 s, increment 1 s1 s - 120 s, increment 1 s
Cycle101010
Stored program15050
Sample volume6×2 mL / 1.5 mL, 2×5 mL24×2 mL / 1.5 mL, 12×5 mL24×2 mL / 1.5 mL, 12×5 mL
Acceleration / deceleration time<2 s<4 s<4 s
Noise<65 db<70 db≤65 db
Power150 W500 W1000 W
Dimension (W×D×H)354×218×206 mm280×360×385 mm330×520×400 mm
Weight8.9 kg25 kg40.0 kg
Power supplyAC 100~240 V, 50/60 HzAC 100~240 V, 50/60 HzAC 100 / AC 240 V, 50/60 Hz

Ordering Information

CodeProduct Description
63-RS-13010-00Bioprep-24 homogenizer
63-RS-13020-00Bioprep-6 homogenizer
63-RS-13030-00Bioprep-24R homogenizer (w/cooling)
63-RS-13011-01Rotor for 24×2.0 mL (Bioprep-24 / Bioprep-24R)
63-RS-13011-02Rotor for 6×5.0 mL (Bioprep-24)
63-RS-13011-30Rotor for 24×2.0 mL (Bioprep-24 / Bioprep-24R)